Search results for " Stent-graft"
showing 10 items of 14 documents
Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery
2014
Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…
Endovascular treatment of abdominal aortic anastomotic pseudoaneurysm. The experience of two centers.
2012
INTRODUCTION: Abdominal aortic pseudoaneurysms are a rare but serious complication of aortic surgery. Treatment with traditional open surgery is associated with a high rate of perioperative mortality and morbidity. Endovascular treatment is less invasive and guarantees lower mortality and morbidity rates. The aim of this study was to evaluate the role of short-, medium- and long-term endovascular treatment of these pseudoaneurysms. MATERIALS AND METHODS: Over the past 10 years, 14 patients with abdominal aortic aneurysms, which developed after prior aortic surgery, underwent endovascular treatment involving implantation of an endoprosthesis at our institutions. Exclusion criteria were emerg…
Total occlusion of aortic arch in a 62-year-old man presenting with acute myocardial infarction
2011
Not available
A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.
2015
Purpose: To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). Methods: Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2–179). All patients had proximal/distal landing zones precluding any standa…
Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin.
2014
A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conven- tional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobac- tam. Patient management consisted of fistula drainage, systemic antibiotic the…
CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies
2013
PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…
Chimney endografting for pararenal aortic pathologies using transfemoral access and the lift technique
2013
Purpose: To present a technique for transfemoral implantation of parallel grafts into the renal arteries in patients with anatomy or morphology that blocks standard antegrade chimney graft delivery. Technique: In a totally percutaneous approach, a 5-F pigtail angiographic catheter is passed into the aorta above the renal arteries via a 0.035-inch hydrophilic guidewire, followed by an 8-F sheath. The target vessel is cannulated with the hydrophilic wire followed by a 5-F reverse curve catheter; the wire is changed for a Rosen wire. The main stent-graft body is delivered and parked at the level of the aortic bifurcation. The Viabahn chimney endograft is advanced ~1 to 2 cm into the target ren…
Chimney and Periscope Grafts Observed Over 2 Years After Their Use to Revascularize 169 Renovisceral Branches in 77 Patients With Complex Aortic Aneu…
2013
Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch to visceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiring chimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned in advance and were not used as bailout. A standardized follow-up protocol including computed tomographic angiography, laboratory testing, and clinical examination…
Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts
2020
Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…
Classification of Chimney EVAR-Related Endoleaks: Insights from the PERICLES Registry
2017
Juxtarenal aortic aneurysms (JAAs) pose significant challenges for endovascular aneurysm repair (EVAR). A short or absent infrarenal neck typically excludes standard EVAR as a viable or reasonable treatment option. In this context, the use of chimney grafts (chEVAR) is gaining in popularity and applicability. These grafts are designed to course in the aortic lumen outside the main stent-graft to maintain normal perfusion to the involved target branches. As such, they may represent a promising and less resource-intensive option for management of JAAs. However, this technical strategy is not without challenges of its own, particularly the inevitable creation of “gutters” that result from the …